1/4" Diameter (actual .246") High Density Cartridge Heaters

Part Numbers and prices listed below are for Cartridge Heaters terminated with Type "N" Leads 10" long. Other Variations available.

Consult Tempco for volume discounts. "Qty" indicates quantity in stock as of 08.01.11

Sheath Length Watts Watt Density Part Number Price
in. (mm) w/in2 (w/cm2) 120V Qty. 240V Qty

1 25.4 50 127 20 HDC00001 28 - 0 29.35
1 25.4 80 204 32 HDC00002 28 - 0 29.35
1 25.4 100 255 40 HDC00003 29 HDC00004 28 29.35
1 25.4 150 382 59 HDC00005 9 - 0 29.35
1 1/8 28.6 100 204 32 HDC00006 53 - 0 30.25
1 1/4 31.8 50 85 13 HDC00007 28 - 0 30.25
1 1/4 31.8 75 127 20 HDC00008 27 - 0 30.25
1 1/4 31.8 100 170 26 HDC00009 23 - 0 30.25
1 1/4 31.8 125 212 33 HDC00010 28 - 0 30.25
1 1/4 31.8 150 255 40 HDC00011 28 HDC00012 27 30.25
1 1/4 31.8 200 340 53 - 0 HDC00013 28 30.25
1 1/4 31.8 225 382 59 - 0 HDC00014 21 30.25
1 1/2 38.1 50 64 10 HDC00015 0 - 0 31.2
1 1/2 38.1 100 127 20 HDC00016 28 HDC00017 28 31.2
1 1/2 38.1 150 191 30 HDC00018 2 HDC00019 28 31.2
1 1/2 38.1 175 223 35 HDC00020 32 HDC00021 29 31.2
1 1/2 38.1 200 255 40 HDC00022 54 HDC00023 0 31.2
1 1/2 38.1 250 318 49 - 0 HDC00024 32 31.2
1 3/4 44.5 75 76 12 HDC00025 27 - 0 33.05
1 3/4 44.5 150 153 24 HDC00026 29 - 0 33.05
1 3/4 44.5 300 306 47 - 0 HDC00027 27 33.05
2 50.8 50 42 7 HDC00028 20 - 0 33.05
2 50.8 80 68 11 HDC00029 29 - 0 33.05
2 50.8 100 85 13 HDC00030 29 HDC00031 0 33.05
2 50.8 125 106 17 HDC00032 28 HDC00033 32 33.05
2 50.8 150 127 20 HDC00034 29 HDC00035 20 33.05
2 50.8 200 170 26 HDC00036 60 HDC00037 20 33.05
2 50.8 250 212 33 HDC00038 29 HDC00039 31 33.05
2 50.8 300 255 40 - 0 HDC00040 15 33.05
2 1/4 57.2 200 146 23 - 0 HDC00041 29 34.75
2 1/2 63.5 150 95 15 - 0 HDC00042 28 34.75
2 1/2 63.5 200 127 20 HDC00043 21 HDC00044 24 34.75
2 1/2 63.5 250 159 25 HDC00045 27 HDC00046 29 34.75
2 1/2 63.5 350 223 35 - 0 HDC00047 16 34.75
2 3/4 69.9 200 113 18 - 0 HDC00048 24 35.85
3 76.2 75 38 6 HDC00049 29 - 0 35.85
3 76.2 100 51 8 HDC00050 28 HDC00051 31 35.85
3 76.2 125 64 10 - 0 HDC00052 15 35.85
3 76.2 150 76 12 HDC00053 30 HDC00054 32 35.85
3 76.2 200 102 16 HDC00055 31 HDC00056 9 35.85
3 76.2 250 127 20 HDC00057 33 HDC00058 33 35.85
3 76.2 300 153 24 HDC00059 28 HDC00060 29 35.85
3 76.2 350 178 28 - 0 HDC00061 28 35.85
3 1/2 88.9 200 85 13 - 0 HDC00062 29 36.5
3 1/2 88.9 300 127 20 HDC00063 17 HDC00064 18 36.5
3 3/4 95.3 300 118 18 - 0 HDC00065 32 40.2
4 101.6 100 36 6 HDC00066 28 - 0 40.2
4 101.6 150 55 9 HDC00067 29 - 0 40.2
4 101.6 175 64 10 HDC00068 17 HDC00069 13 40.2
4 101.6 200 73 11 HDC00070 25 HDC00071 26 40.2
4 101.6 250 91 14 HDC00072 21 HDC00073 12 40.2
4 101.6 300 109 17 HDC00074 87 HDC00075 26 40.2
4 101.6 400 146 23 - 0 HDC00076 28 40.2
4 1/2 114.3 125 40 6 HDC00077 17 - 0 42
4 1/2 114.3 200 64 10 HDC00078 27 - 0 42
4 1/2 114.3 500 159 25 - 0 HDC00079 17 42
5 127 200 57 9 - 0 HDC00080 25 43.9
5 127 250 71 11 - 0 HDC00081 28 43.9
5 127 350 99 15 HDC00082 28 HDC00083 28 43.9
5 127 400 113 18 HDC00084 18 HDC00085 29 43.9
5 3/4 146.1 350 85 13 HDC00086 78 HDC00087 132 47.4
6 152.4 150 35 5 HDC00088 27 - 0 47.4
6 152.4 200 46 7 - 0 HDC00089 28 47.4
6 152.4 300 69 11 HDC00090 28 HDC00091 30 47.4
6 152.4 400 93 14 HDC00092 13 HDC00093 14 47.4
6 152.4 450 104 16 HDC00094 20 HDC00095 30 47.4
6 152.4 600 139 22 - 0 HDC00096 27 47.4
6 1/2 165.1 500 106 17 HDC00097 16 HDC00098 42 49.05
7 177.8 600 118 18 - 0 HDC00099 29 50.95
7 1/2 190.5 525 95 15 HDC00100 19 - 0 52.9
8 203.2 300 51 8 HDC00101 24 - 0 54.65
8 203.2 600 102 16 - 0 HDC00102 20 54.65
9 228.6 675 101 16 - 0 HDC00103 17 58.3
9 1/2 241.3 525 74 12 HDC00104 23 - 0 60.1
10 254 750 101 16 - 0 HDC00105 21 61.85
11 279.4 600 73 11 - 0 HDC00106 12 65.5
13 330.2 725 74 12 - 0 HDC00107 27 74.15


Amperage Limitations

Diameter 1/4" 5/16" 3/8" 1/2" 5/8" 3/4"
Max Amperage
See Next Line for Exceptions
4.4 4.5 6.7 10.5 23.0 23.0
Maximum Amperage for
Types F and W Terminations
2.5 2.5 4.0 7.0 10.0 10.0



SHEATH LENGTH
Sheath length is the actual insertion length of the heater, not the overall length of the heater. Sheath length tolerance: + or - 3/32 OR + or - 2%, whichever is greater, except for Type F and W terminations. Sheath length tolerance for Type F and W terminations: + or - 3/16 OR + or - 2%, whichever is greater.